Skip to main content

Accelerometer measurement of upper extremity movement after stroke: a systematic review of clinical studies

Abstract

The aim of this review was to identify and summarise publications, which have reported clinical applications of upper limb accelerometry for stroke within free-living environments and make recommendations for future studies. Data was searched from MEDLINE®, Scopus, IEEExplore and Compendex databases. The final search was 31st October 2013. Any study was included which reported clinical assessments in parallel with accelerometry in a free-living hospital or home setting. Study quality is reflected by participant numbers, methodological approach, technical details of the equipment used, blinding of clinical measures, whether safety and compliance data was collected. First author screened articles for inclusion and inclusion of full text articles and data extraction was confirmed by the third author. Out of 1375 initial abstracts, 8 articles were included. All participants were stroke patients. Accelerometers were worn for either 24 hours or 3 days. Data were collected as summed acceleration counts over a specified time or as the duration of active/inactive periods. Activity in both arms was reported by all studies and the ratio of impaired to unimpaired arm activity was calculated in six studies. The correlation between clinical assessments and accelerometry was tested in five studies and significant correlations were found. The efficacy of a rehabilitation intervention was assessed using accelerometry by three studies: in two studies both accelerometry and clinical test scores detected a post-treatment difference but in one study accelerometry data did not change despite clinical test scores showing motor and functional improvements. Further research is needed to understand the additional value of accelerometry as a measure of upper limb use and function in a clinical context. A simple and easily interpretable accelerometry approach is required.

Introduction

Body worn motion sensors provide an opportunity for non-invasive, objective and accurate observation of patients’ movements during research and clinical rehabilitation [16]. These range from simple physical activity monitors (e.g. pedometers) [1] to more complex instruments that can capture precise limb position in a three-dimensional space (e.g. a combined accelerometer-gyroscope-magnetic field) [2]. The continuous development of technology and data analysis methods has resulted in an increasing number of proof-of-concept and validation studies [3, 4]. However for motion sensor approaches to fully explore recovery mechanisms or assist clinicians during therapeutic decision-making, they must reflect patient activity in real world settings.

Being small, light and affordable, accelerometers are an attractive technology for measurement of upper extremity movement. As loss of arm function is common after stroke [5], they have already been used to record activity (i.e. the amount of use per time unit) [7] and/or discriminate active from inactive periods [6, 8]. Although the information derived from standard accelerometers is limited to changes in speed and direction, if therapeutic applications are demonstrated in hospital and home settings then a large number of patients could benefit.

A broad systematic review of accelerometer applications after stroke has previously reported that accelerometers yield valid and reliable data about the physical activity of patients, but the clinical implications were unclear because of the limited evidence available [9]. The search was undertaken in October 2008 and has not been repeated to include more recent publications which focus on clinically relevant outcomes. Subsequent studies have included a heterogeneous range of upper limb impairment and function measures, and used a variety of statistical approaches to examine for associations with different accelerometer data formats. Consequently it is difficult to appreciate the current state of development of clinical accelerometer applications.

The aim of this systematic review was to identify and summarise publications that have reported clinical applications of upper limb accelerometry amongst stroke populations within free-living hospital or home environments, and thereby make recommendations for future clinical practice and research. To maintain clinical relevance, we sought to include only studies from real-world settings which reported clinical assessments in parallel with motion data.

Review

Methods

We systematically searched the published literature regarding the use of upper limb accelerometry amongst stroke patients to answer the following questions:

  1. (1)

    What are the clinically relevant research applications of upper limb accelerometers in a free-living hospital or home environment?

  2. (2)

    What types of accelerometers have been described and how were they used?

  3. (3)

    How was data collected and analysed?

  4. (4)

    How do the data measurements obtained relate to clinical assessments in a way that would be useful for clinicians and researchers?

The inclusion criteria were peer-reviewed original studies that (1) used movement sensors in a stroke population from a free-living clinical or domiciliary setting, (2) created a kinematic description of upper limb movement from sensor data, (3) used stand-alone accelerometers which did not require an external reference point (e.g. an electromagnetic field), (4) compared the kinematic data with a clinical assessment of impairment or function. We did not include articles that reported data (1) only relating to validity, reliability or algorithm and/or sensor development without any clinical comparison, (2) from sensors used in a visual feedback system or video game, (3) reflecting modification of the accelerometer output by other devices (e.g. from a separate gyroscope), and (4) where movement was limited to a very specific environment, function and/or task e.g. during performance of a subset of upper limb motor tasks from the Fugl-Meyer Assessment [10] or only during reaching [7]. Due to the small number of publications anticipated, all research designs were included and study quality was not formally rated. However quality is reflected by the study information reported including participant numbers, population details provided, methodological approach taken, technical description of the equipment used, blinding of clinical measures and whether safety and compliance data were collected.

The search strategy used for all databases is described in Appendix 1. Electronic databases were searched online through the Newcastle University library system: MEDLINE® (1946 to October Week 4 2013), Scopus (All years –October 2013), IEEExplore (1999–2013), and Compendex (1884–2014). The final search was 31st October 2013. The first author initially screened articles for inclusion based upon title and abstract, removed duplicates, retrieved full-text papers and selected final articles according to the inclusion and exclusion criteria (Figure 1). Inclusion of full text articles and data extraction was confirmed by the third author.

Figure 1
figure 1

Flow of information through the different search phases of a systematic review based on PRISMA 2009 guidelines. Four search engines (i.e. MEDLINE, Scopus, IEEExplore and Compendex) were used to identify the relevant literature. After the screening based on title and abstract and removal of duplicates, 18 articles were selected. After the selection based on the full text article, 8 final articles were included in the current review.

Results

Upper limb accelerometry applications in clinical stroke research

Eight articles fitted the inclusion criteria (Table 1). All included stroke patients without other neurological conditions represented. Three described rehabilitation interventions where accelerometer data were collected to explore mechanisms and/or as an outcome measure, including two randomised controlled trials. Age range was reported by three studies (35 to 94 years) [8, 11, 12] and the average age was reported by five studies [1317] (Table 1). Gender distribution favoured male and was 65% overall. The inclusion criteria for studies were six mild to moderate [8, 1114] and one severe [15] upper extremity impairment. The level of motor impairment was not reported [16]. Patients with excessive spasticity were excluded in two studies [13, 17], shoulder pain was an exclusion for two studies [15, 17] and wheelchair bound participants were excluded by one study [8]. Participants were required to have no or minimal cognitive deficit in all studies.

Table 1 Overview of the selected articles

Applications of accelerometers in the selected studies were grouped into four main categories: (1) description of upper limb usage after stroke [11]; (2) assessment of the effect of therapeutic interventions such as robot-assisted therapy [17], constraint-induced movement therapy [16] and sub-acute stroke rehabilitation [15]; (3) comparison of real-world upper limb use with various measures of upper limb impairment and function; and (4) examination of the reliability and validity of a specific clinical scale such as the ABILHAND questionnaire [13] and Motor Activity Log [14]. No studies were identified which used accelerometer output to modify a therapeutic intervention in the same cohort. Compliance with accelerometry was reported only in the study by Liao et al. [17]: “all 20 study participants completed the study and no discomfort when wearing the device was reported and overall compliance was good”.

Accelerometer type, site and duration

Three studies used tri-axial accelerometers [8, 16, 17], one study two-axial [14], two studies uni-axial accelerometers [11, 12] and the type of the accelerometer were not reported by two studies [13, 15]. All participants wore accelerometers on both wrists for either a single 24 hr period [1113] or 3 consecutive days [8, 1417]. Only Lang et al. explained their choice of data collection period: “the 24 hour period was chosen because: 1) that is the length of the day, enabling to capture activity that might occur outside of the typical workday or therapy hours, and 2) people with hemiparesis and controls were less interested in participating or less-compliant with wearing them if they had to be worn for longer periods” [11].

Accelerometry data collection and analysis

Data were collected either as the summed acceleration counts over a specified time [8, 14, 16, 17], or as dichotomized data representing the duration of active and inactive periods [11, 12]. Different approaches were reported for defining a unit of arm activity, with data capture epochs varying from 1 second to 1 minute. Activity of both impaired and unimpaired upper extremities were measured and reported in all studies. A ratio of impaired to unimpaired arm activity was calculated for all studies except Rand et al. [16] and Lang et al. [12]. Two studies explained their choice for using a ratio as a main outcome measure: Liao et al. [17] chose arm activity ratio because the mean activity value of each arm would be subject to interference by other factors, such as walking pattern [18]; Uswatte et al. [14] explained that accelerometers were worn on both wrists during a trial of constraint induced movement therapy because a single unit on the impaired arm might cue use of that extremity and thereby confound measurement of treatment outcome and previous validation studies had suggested that the ratio of recordings controlled better for variations in overall levels of physical activity [1, 19].

In two studies the participants were asked to keep a diary to assist with accelerometry data analysis [8, 12]: Thrane et al. [12] asked participants to note in a diary when accelerometers were removed, travel and sleep in order to exclude these periods from analysis. Van der Pas et al. [8] asked participants to record times for going to sleep/getting up and trigger an event marker on the device. In the study by Rand et al. [16], a participant completed diary was not used but the activity counts of arm swing while walking were eliminated (5 consecutive steps or more in one epoch) to increase data specificity for goal directed hand usage.

Clinical measures vs. accelerometry data

The correlation between various clinical test scores and upper limb accelerometry was examined in five studies (Table 2). Accelerometry data correlated significantly with most clinical tests of impairment such as active range of motion [11], muscle strength [11], Fugl-Meyer Assessment subscale for upper extremity [11], and with clinical tests of upper extremity function such as Action Research Arm Test (ARAT) [11], Wolf Motor Function Test (WMFT) [11], Functional Independence Measure (FIM) for motor and upper extremity function [11], different scales of Motor Activity Log (MAL) [8, 14], Stroke Impact Scale (SIS) Hand Function Subscale [8], a test of manual ability of the upper extremity ABILHAND [13] and Nottingham Extended Activities of Daily Living (NEADL) [13]. A lack of correlation was found with the Modified Ashworth Scale [11], composite light touch [11], joint position sense [11] and SIS Mobility Subscale [8].

Table 2 Comparisons of accelerometer data and clinical scales

Consistent with studies in controlled settings, Thrane et al. [12] found a stronger correlation between a clinical assessment of impairment (Fugl-Meyer Assessment (FMA) and the movement duration ratio between the least affected and more affected arm (r = -0.851, p < 0.001) than between the FMA and raw accelerometer data (r = 0.601, p < 0.001). However Van der Pas et al. [8] found a high correlation between unilateral (affected arm) and bilateral (ratio) accelerometry (the number of counts per time unit representing movement ‘intensity’) and MAL-AOU (amount of use) and MAL-QOM (quality of movement) scales, suggesting that both unilateral and bilateral arm accelerometry are valid methods for assessing arm activity related to function in daily life of patients after stroke.

Thrane et al. [12] found a variation in arm movement ratio (AMR) from accelerometer readings especially in the upper range (less impairment) of FMA: in the FMA range of 43–47, the AMR varied from a normal level of 1.2 to 2.5, indicating 2.5 times greater movement of the less-affected arm which could indicate perceptual difficulties or “learned non-use” amongst some participants. No cofactors interfered with this relationship in the two-factor regression models (age, gender, days since stroke, initial stroke severity, apraxia, and lower extremity function). Hand dominance and choice of tasks could also explain AMR variations in subjects with the same level of motor function, however incomplete data prevented the authors from further exploration of this finding and the clinical implication is not clear [12].

The efficacy of an intervention was tested in three studies [1517] where accelerometry and clinical tests data were collected in parallel. In two of these, the accelerometer data ratio between the impaired and unimpaired arm and clinical test scores both detected a difference from baseline to post-treatment [15, 17]. The FMA [15, 17], MAL [15, 17], Functional Independence Measure [17] and active range of motion of the upper limb [15] were used as outcome measures. However, in the study by Rand et al. [16], there was a discrepancy between the clinical test scores and accelerometry: clinical test scores showed motor and functional improvements while upper extremity accelerometry data (mean activity counts) did not change (Table 2). Although this discrepancy may reflect methodological factors, accelerometer data might be a better representation of real world activity, which is influenced by many more factors than just motor performance.

Discussion

Measurement of upper extremity movement by accelerometry during day-to-day activities in hospital or at home has the potential to provide additional valuable information about recovery after stroke. The eight studies identified for the present review, including a large multicentre clinical trial (n = 222) [14] and a prospective randomised controlled trial (n = 20) [17], have demonstrated that accelerometry can be systematically applied as a method for measuring overall upper extremity activity. However it is still uncommon that motion sensors are used to inform the development of new clinical rehabilitation approaches.

Accelerometry data correlated well with the clinical tests of impairment and function, apart from measures which do not directly reflect upper limb motor function such as tone, sensation and mobility. Only the study by Rand et al. [16] reported that accelerometry failed to detect change in upper extremity usage after a rehabilitation programme whilst clinical tests showed a significant decrease in impairment and improved function. Interestingly, this was one of the two studies where the ratio of impaired to unimpaired arm usage was not calculated and reported the usage of impaired upper extremity only, but it should be also considered that rehabilitation approach, patient motivation and learned non-use might be reasons why clinical recovery is not reflected in daily upper limb activity [16]. Improvements in stand-alone clinical assessments without matching accelerometer readings might indicate that participants have not translated motor recovery into daily life. Rand et al. [16] suggested that the gap between the recovery of capacity (i.e. clinical measurements) and the lack of improvement in performance (i.e. daily use of the upper extremities according to accelerometer data) provides a useful guide for clinicians. If this is demonstrated by appropriately designed studies then feedback of accelerometer data to patients and clinicians may have a therapeutic role. Improving the interpretation of accelerometry data with clinical questionnaires (e.g. the Motor Activity Log and ABILHAND) could allow researchers to capture a wider spectrum of change in daily function for stroke patients receiving rehabilitative therapies [8, 13, 14, 17]. In several studies participants were asked to keep a diary describing their everyday activities such as periods of walking, sitting, driving car etc. [8, 12]. However, using activity log sheets in addition to accelerometry will set certain limitations for study recruitment due to the extra time, effort and motivation required from participants and researchers, and is only feasible if the participant can write, or a carer can reliably complete log sheets on their behalf.

Accelerometry data were collected either during 24 hours or 3 consecutive days, which was justified by only one author [11]. Other studies mostly referred to the published protocols by Uswatte et al. [1, 6] where data collection is over three consecutive days, possibly because the accelerometer continuous recording capacity is approximately 72 h. It is unclear how long accelerometry data should be collected for in order to obtain a meaningful description of upper extremity usage in a real-world environment [20, 21]. It has been suggested that 7 to 10 and 14 to 21 days of assessment are required to reliable observe (i.e. R = 0.80), total activity in healthy men and women, respectively [22]. In contrast, 21 to 28 days are required for reliable observation of non-occupational activity patterns in healthy men and women [22]. Measuring physical activity levels and patterns of patients during neurological rehabilitation will be more challenging, as the duration and amplitude of activities will be limited by changes in motor function [11]. In community settings it has been shown that adults participants are more active on Saturdays than Sundays [22, 23], and for a real-world examination of motor behaviour it would be important to balance the days of the week [21].

Further interpretation of data still has limitations, mainly because of contamination by other activities that did not include purposeful arm movement e.g. walking. Attempts have been made to overcome these limitations by using special data collection and analysis methods to prevent overestimation of upper extremity use. Most of the studies included in the present review defined upper extremity use as any time when accelerometer data suggested movement. However there were alternative approaches. Rand et al. [16] defined upper extremity usage as the number of activity counts during a specified time. Liao et al. [17] defined upper extremity usage as the area under the transducer signal curve proposing that this detected subtle change in hemiplegic arm activity and so was more appropriate for rehabilitation studies than a threshold approach [9, 24].

Six studies out of eight used the ratio of impaired to unimpaired arm as the outcome of upper extremity usage [8, 1114, 17], three of the six studies reported the ratio only [13, 15, 17]. Whilst the ratio can aid correction for the variability in overall physical activity, its interpretation is limited if the absolute activity of impaired and unimpaired arms is not reported. For example, Lang et al. [11] found that the activity duration of the impaired arm was less than unimpaired, however, the usage of both was less than that of healthy controls. They also found that the hours of dominant and non-dominant upper extremity use were not different [11] and that affected and unaffected upper extremity use was positively correlated, supporting observations that upper extremities are most often used together to perform bimanual tasks during daily activity [11]. In addition, Van der Pas [8] found that movement of the affected arm after stroke was related to performance of functional activities when that arm was dominant pre-stroke. Therefore when upper extremity usage is reported as a ratio, the underlying data is still dependent upon intra- and inter-individual variations in bilateral upper extremity activity. The personal choice of tasks attempted will also influence conclusions which can be drawn when comparing between individuals in real-world settings, which has implications for use of accelerometry during rehabilitation programmes where patient and therapist select repetitive movements from a menu, e.g. [25].

The type of sensors varied from uni- to multiple-axis accelerometers. Although a strong positive correlation between the output from uniaxial and multiple axis accelerometers have been reported [2], the validity coefficients reported for multiple axis units have been higher than those reported for uniaxial models [2]. Importantly, it is impossible to calculate a minimal clinical difference for arm use by a uniaxial accelerometer because they only measure in a single plane of movement [9]. Thus, multiple axis accelerometers should be preferred to uniaxial devices.

Study limitations

Although we sought to identify studies in free-living rather than controlled laboratory settings, the patients included were still not typical of the stroke population, being younger than the average age of stroke occurrence in UK (~ 75 y) [26] and more often male. There was a tendency to use accelerometry amongst patients with moderate to mild impairment. Time since stroke varied across a large range and it is likely that contact with rehabilitation services would have varied similarly. There was no data safety or tolerance reported (except the comment by Liao et al. [17]). These factors reduce the relevance of current evidence for typical neurological rehabilitation populations. Identifying and overcoming difficulties that limit the use of real-world accelerometry across a whole range of patients will be a challenging but an important focus for future studies.

Conclusions

Real-world usage of the upper extremity during stroke rehabilitation is still not yet well described and we require better knowledge of how to interpret different variables of accelerometry against clinical measures which holds meaning for clinicians and patients. Recommendations from this review of recent studies are:

  • Clinical measures are still required to provide context for interpretation in case the individual’s recovery is not reflected through real world accelerometer data e.g. due to learned non-use

  • The ratio between impaired and unimpaired sides is the standard approach for upper limb accelerometry but hand dominance might require further consideration depending upon individually chosen rehabilitation goals

  • Diaries should be used for at least a proportion of the monitoring period in order to relate individual accelerometer data to background levels of activity.

  • Simple, user-friendly cost-effective and easily interpretable upper limb accelerometry methods are still required if this is to be a useful tool to monitor patients’ progress alongside clinical assessments of motor recovery.

Appendix 1: search strategy

MEDLINE: (stroke* and rehabilit* and accelerometer*).mp. [mp = title, abstract, original title, name of substance word, subject heading word, keyword heading word, protocol supplementary concept, rare disease supplementary concept, unique identifier]

Scopus: TITLE-ABS-KEY(stroke* AND rehabilit* AND accelerometer*)

IEEExplore: stroke* and rehabilit* and accelerometer*

Compendex: ((((stroke*) WN KY) AND ((rehabilit*) WN KY)) AND ((accelerometer*) WN KY))

References

  1. Uswatte G, Foo WL, Olmstead H, Lopez K, Holand A, Simms LB: Ambulatory monitoring of arm movement using accelerometry: An objective measure of upper-extremity rehabilitation in persons with chronic stroke. Arc Phys Med 2005,86(7):1498-1501. 10.1016/j.apmr.2005.01.010

    Article  Google Scholar 

  2. Trost SG, McIver KL, Pate RR: Conducting accelerometer-based activity assessments in field-based research. MSSE 2005,37(11 Suppl):S531-S543.

    Google Scholar 

  3. Wong WY, Wong MS, Lo KH: Clinical applications of sensors for human posture and movement analysis: a review. Prosthet Orthot Int 2007,31(1):62-75. 10.1080/03093640600983949

    Article  PubMed  Google Scholar 

  4. Zhou HY, Hu HS: Human motion tracking for rehabilitation-a survey. Biomed Signal Proces 2008,3(1):1-18. 10.1016/j.bspc.2007.09.001

    Article  CAS  Google Scholar 

  5. Lawrence ES, Coshall C, Dundas R, Stewart J, Rudd AG, Howard R, Wolfe CD: Estimates of the prevalence of acute stroke impairments and disability in a multiethnic population. Stroke 2001,32(6):1279-1284. 10.1161/01.STR.32.6.1279

    Article  CAS  PubMed  Google Scholar 

  6. Uswatte G, Giuliani C, Winstein C, Zeringue A, Hobbs L, Wolf SL: Validity of accelerometry for monitoring real-world arm activity in patients with subacute stroke: evidence from the extremity constraint-induced therapy evaluation trial. Arch Phys Med 2006,87(10):1340-1345. 10.1016/j.apmr.2006.06.006

    Article  PubMed  Google Scholar 

  7. Hester T, Hughes R, Sherrill DM, Knorr B, Akay M, Stein J, Bonato B: Using wearable sensors to measure motor abilities following stroke. International Workshop on Wearable and Implantable Body Sensors Networks (BSN’06) 2006, 5-8.

    Chapter  Google Scholar 

  8. van der Pas SC, Verbunt JA, Breukelaar DE, van Woerden R, Seelen HA: Assessment of arm activity using triaxial accelerometry in patients with a stroke. Arch Phys Med 2011,92(9):1437-1442. 10.1016/j.apmr.2011.02.021

    Article  PubMed  Google Scholar 

  9. Gebruers N, Truijen S, Engelborghs S, Nagels G, Brouns R, De Deyn PP: Actigraphic measurement of motor deficits in acute ischemic stroke. Cerebrovasc Dis 2008,26(5):533-540. 10.1159/000160210

    Article  CAS  PubMed  Google Scholar 

  10. Zhang M, Lange B, Chang CY, Sawchuk AA, Rizzo AA: Beyond the standard clinical rating scales: fine-grained assessment of post-stroke motor functionality using wearable inertial sensors. Conf Proc IEEE Eng Med Biol Soc 2012, 2012: 6111-6115.

    PubMed  Google Scholar 

  11. Lang CE, Wagner JM, Edwards DF, Dromerick AW: Upper extremity use in people with hemiparesis in the first few weeks after stroke. JNPT 2007, 31: 56-63.

    PubMed  Google Scholar 

  12. Thrane G, Emaus N, Askim T, Anke A: Arm use in patients with subacute stroke monitored by accelerometry: Association with motor impairment and influence on self-dependence. J Rehabil Med 2011,43(4):299-304. 10.2340/16501977-0676

    Article  PubMed  Google Scholar 

  13. Wang TN, Lin KC, Wu CY, Chung CY, Pei YC, Teng YK: Validity, responsiveness, and clinically important difference of the ABILHAND questionnaire in patients with stroke. Arch Phys Med 2011,92(7):1086-1091. 10.1016/j.apmr.2011.01.020

    Article  PubMed  Google Scholar 

  14. Uswatte G, Taub E, Morris D, Light K, Thompson PA: The motor activity log-28: Assessing daily use of the hemiparetic arm after stroke. Neurology 2006,67(7):1189-1194. 10.1212/01.wnl.0000238164.90657.c2

    Article  CAS  PubMed  Google Scholar 

  15. Taub E, Uswatte G, Bowman MH, Mark VW, Delgado A, Bryson C, Morris D, Bishop-McKay S: Constraint-induced movement therapy combined with conventional neurorehabilitation techniques in chronic stroke patients with plegic hands: A case series. Arch Phys Med 2013,94(1):86-94. 10.1016/j.apmr.2012.07.029

    Article  PubMed  PubMed Central  Google Scholar 

  16. Rand D, Eng JJ: Disparity between functional recovery and daily use of the upper and lower extremities during subacute stroke rehabilitation. Neurorehabil Neural Repair 2012,26(1):76-84. 10.1177/1545968311408918

    Article  PubMed  PubMed Central  Google Scholar 

  17. Liao WW, Wu CY, Hsieh YW, Lin KC, Chang WY: Effects of robot-assisted upper limb rehabilitation on daily function and real-world arm activity in patients with chronic stroke: a randomized controlled trial. Clin Rehabil 2012,26(2):111-120. 10.1177/0269215511416383

    Article  PubMed  Google Scholar 

  18. Reiterer V, Sauter C, Klosch G, Lalouschek W, Zeitlhofer J: Actigraphy–a useful tool for motor activity monitoring in stroke patients. Eur Neurol 2008,60(6):285-291. 10.1159/000157882

    Article  PubMed  Google Scholar 

  19. Uswatte G, Taub E: Participant-centered and objective measures of real-world arm function in persons with stroke. Circulation 2004,109(20):E243.

    Google Scholar 

  20. Heil DP, Brage S, Rothney MP: Modeling physical activity outcomes from wearable monitors. MSSE 2012,44(1 Suppl 1):S50-S60.

    Google Scholar 

  21. Masse LC, Fuemmeler BF, Anderson CB, Matthews CE, Trost SG, Catellier DJ, Treuth M: Accelerometer data reduction: a comparison of four reduction algorithms on select outcome variables. MSSE 2005,37(11 Suppl):S544-S554.

    Google Scholar 

  22. Matthews CE, Hebert JR, Freedson PS, Stanek EJ 3rd, Merriam PA, Ebbeling CB, Ockene IS: Sources of variance in daily physical activity levels in the seasonal variation of blood cholesterol study. Am J Epidemiol 2001,153(10):987-995. 10.1093/aje/153.10.987

    Article  CAS  PubMed  Google Scholar 

  23. Baranowski T, Smith M, Thompson WO, Baranowski J, Hebert D, de Moor C: Intraindividual variability and reliability in a 7-day exercise record. MSSE 1999,31(11):1619-1622.

    CAS  Google Scholar 

  24. Moran DS, Heled Y, Gonzalez RR: Metabolic rate monitoring and energy expenditure prediction using a novel actigraphy method. Med Sci Monit 2004,10(11):MT117-MT120.

    PubMed  Google Scholar 

  25. Harris JE, Eng JJ, Miller WC, Dawson AS: A self-administered graded repetitive arm supplementary program (GRASP) improves arm function during inpatient stroke rehabilitation: a multi-site randomized controlled trial. Stroke 2009,40(6):2123-2128. 10.1161/STROKEAHA.108.544585

    Article  PubMed  Google Scholar 

  26. Sudlow CL, Warlow CP: Comparing stroke incidence worldwide: what makes studies comparable? Stroke 1996,27(3):550-558. 10.1161/01.STR.27.3.550

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marika Noorkõiv.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

The first author - literature search, filtered abstracts, extracted data and prepared the manuscript. The second author - prepared the manuscript. The third author - conception of the topic, data review and prepared the manuscript. All authors read and approved the final manuscript.

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Noorkõiv, M., Rodgers, H. & Price, C.I. Accelerometer measurement of upper extremity movement after stroke: a systematic review of clinical studies. J NeuroEngineering Rehabil 11, 144 (2014). https://doi.org/10.1186/1743-0003-11-144

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1743-0003-11-144

Keywords